13. Global Parameters#
Parameters listed below can be accessed via the rcGetParameterValue
and rcSetParameterValue functions. These parameters control the
general function of Reactis for Simulink. Each parameter described here can
also be accessed from the Global Settings dialog (invoked via File
→ Global Settings...) in the main window of the Reactis for C GUI. The
parameter names and allowed values are listed below. For a more detailed
description of the functionality of the parameters, see Chapter 4 of the
Reactis for C User’s Guide.
13.1. General#
Parameter Name |
Allowed Values |
Description |
|---|---|---|
|
en_EN, ja_JP |
The language used in the Reactis GUI to English (en_EN) or Japanese (ja_JP). |
|
string |
The character set to be used when reading C source files. |
|
0, false, 1, true |
Enables automatic checking for updates. |
|
0, false, 1, true |
Enables creation of .rtp files, which contain the Tester parameters used to create a test suite. |
|
0, false, 1, true |
Enables the Reactis logging facility. Enabling this can decrease performance and may generate large log files. Only enable this if asked to do so by the Reactis support team. |
|
string |
Determines what will be written to the Reactis log file (see parameter EnableLogging). If you are asked to create a log file by the Reactis support team, the required LogLevel string will be indicated. |
|
string |
The pathname of the Reactis log file, which is created when logging is enabled (see parameter EnableLogging). |
13.2. C Code#
Parameter Name |
Allowed Values |
Description |
|---|---|---|
|
string |
Specifies the directory where Reactis stores files that it creates and uses. |
13.3. Cosimulation#
|
0, false, 1, true |
If true, Reactis for C will allow the user to link to a Reactis (for Simulink) session to co-simulate a model and the C code under test. |
|---|---|---|
|
number |
The lower limit of the range of ports to be used for cosimulation. |
|
number |
The upper limit of the range of ports to be used for cosimulation. |
13.4. User Info#
Parameter Name |
Allowed Values |
Description |
|---|---|---|
|
string |
Name of the current user. Setting this to |
|
string |
Phone number of the current user. This information will be reported to the license server. |
13.5. License#
Parameter Name |
Allowed Values |
Description |
|---|---|---|
|
string |
The IP address or host name of a server running the Reactis License Manager software. |
|
number |
The maximum idle time (in seconds). When the limit is reached, Reactis will release any floating licenses it is using. |