Bug: Incorrect output of Math Function block if configured for signed power output
| Submitted | Product | Status | ||
|---|---|---|---|---|
| 2023-01-03 | Reactis for Simulink | Resolved in 2022.2.1 (released Jan 20, 2023; release notes) Resolved in 2022.0.3 (released Jan 20, 2023; release notes) | ||
|
If a Math Function block is configured for the "pow" function (x^y) and the "Signed Power" box is checked then for x=0 and y=0 in Reactis the block outputs 0 whereas the expected output would be 1. | ||||