Back to all issues

Issue 5538

Bug: Reading of non-word-aligned structures sometimes fails


SubmittedProductStatus
2024-09-24Reactis for SimulinkResolved in 2024.0.2 (released Oct 28, 2024; release notes)
Resolved in 2023.2.4 (released Oct 28, 2024; release notes)

If a struct type is not word-aligned, which can happen when all the members are not word-aligned (e.g., all the members have type "char"), reading the structure value may produce a "misaligned index" bug message.