Back to all issues

Issue 5602

Bug: Error "Could not evaluate signal '...' in data dictionary"


SubmittedProductStatus
2024-12-13Reactis for SimulinkResolved in 2024.2.1 (released Jan 30, 2025; release notes)
Resolved in 2024.0.4 (released Jan 30, 2025; release notes)

If all of the following hold:

- a model has a data dictionary attached

- the "Enable access to base workspace" is enabled

- min/max values for a top-level input port reference variables that are present in the model workspace but NOT in the data dictionary

Then Reactis produces the following error during "Inferring data types" stage of the model import:

Simulink reported the following error during type inference :
??? Could not evaluate 'testsignal' in data dictionary
 in file reactis_getinportrange.p, function myeval() (line 56)
 in file reactis_getinportrange.p, function reactis_getinportrange() (line 4)
 in file reactis_getinportranges.p, function reactis_getinportranges() (line 0)