Back to all issues

Issue 5623

Bug: Bug: unable to find sample rate for latched inport


SubmittedProductStatus
2025-01-24Reactis for SimulinkResolved in 2024.2.2 (released Jun 03, 2025; release notes)
Resolved in 2024.0.5 (released Jun 03, 2025; release notes)

If the Inport block of a triggered subsystem has the option "Latch input by delaying outside signal" checked and the triggered subsystem is in a function-call subsystem, then Reactis produces the error "Bug: unable to find sample rate for latched inport" when enabling simulation.

Also, if the Inport block of a function-call subsystem has the option "Latch input by delaying outside signal" checked while disabled (because it is not used for a function-call subsystem) and the function-call subsystem does not have its trigger port connected, i.e. the model is not valid, then Reactis produces the error "Bug: unable to find sample rate for latched inport" when enabling simulation instead of the error "Error: Illegal function-call connection".