Back to all issues

Issue 5982

Bug: Reachability analysis may revert to using limited solver support when there is no issue with the solver


SubmittedProductStatus
2026-06-19Reactis for SimulinkResolved in 2026.0.1 (released Oct 30, 2026; release notes)
Resolved in 2025.2.3 (released Oct 30, 2026; release notes)
Open in 2025.0.4, 2024.2.4

When enabling Simulator or running Tester, the backend may be restarted using the legacy solver interface because reachability analysis in the backend has not sent a life sign within the maximum possible solver time. This ensures that an issue with the solver does not prevent reachability analysis from completing. However, a delay may occur in during reachability analysis (due to a Delay block with > 50,000 steps) that is not related to the solver causing a delay between life signs that results in the legacy solver being used.