April 29, 2020

Dear Reactis User:

Reactis V2019.2.2 and V2019.0.5 as well as Reactis for C V2019.0.1 and V2018.0.2 are now available.

Reactis V2019.2.2

The following bugs were fixed since V2019.2.1:

  • "Error: Data Type Mismatch" for some Validator expressions using "t" for simulation time (#4565)
  • "Error while loading S-Function" when using Interpolation block with MATLAB R2015aSP1 Update 3 (#4561)
  • "Error: Undefined variable" in some cases of multiple masks using the same variable names (#4558)
  • "Error: Signal '...' not found in bus" if signal name set at input of SignalSpecification block (#4555)
  • Reactis hangs in "inferring types" phase during model import (#4552)
  • Reactis does not properly detect non-virtual buses in some cases (#4549)
  • Nested masks not working properly in Reactis in some cases (#4545)
  • Transition order for nested (subcharted) box states incorrect in some cases (#4541)
  • "Error: Undefined variable" for Delay blocks set to a delay length of zero (#4534)
  • "bug: invalid pointer" for some models with merge blocks (#4531)
  • Errors for Discrete Filter or Discrete Transfer Function when using input ports for numerator or denominator (#4529)
  • Configuration variables with many elements not displaying properly in "Edit Text" dialog (#4526)
  • "bug: uncaught exception: Match" for some DataStoreMemory blocks operating on arrays of buses (#4523)
  • 3-dimensional Simulink.Parameter configuration variable reports error (#4519)
  • Invalid pointers created if BusAssignment blocks are connected to Merge blocks in some cases (#4515)
  • "error: Invalid system path" when calling rsRsiSetSystemCoverageTracking API for cumulative system (#4511)
  • If multiple configuration variables violate constraints, Reactis only produces a warning for one (#4501)
  • Bad error message for out-of-range indices in Assignment block (#4497)
  • "Error: Data Type Mismatch" for some models with For or While subsystems (#4494)

Reactis V2019.0.5

The following bugs were fixed since V2019.0.4:

  • "Error: Data Type Mismatch" for some Validator expressions using "t" for simulation time (#4565)
  • "Error while loading S-Function" when using Interpolation block with MATLAB R2015aSP1 Update 3 (#4561)
  • "Error: Undefined variable" in some cases of multiple masks using the same variable names (#4558)
  • "Error: Signal '...' not found in bus" if signal name set at input of SignalSpecification block (#4555)
  • Reactis hangs in "inferring types" phase during model import (#4552)
  • Reactis does not properly detect non-virtual buses in some cases (#4549)
  • Nested masks not working properly in Reactis in some cases (#4545)
  • Transition order for nested (subcharted) box states incorrect in some cases (#4541)
  • "Error: Undefined variable" for Delay blocks set to a delay length of zero (#4534)
  • "bug: invalid pointer" for some models with merge blocks (#4531)
  • Configuration variables with many elements not displaying properly in "Edit Text" dialog (#4526)
  • "bug: uncaught exception: Match" for some DataStoreMemory blocks operating on arrays of buses (#4523)
  • 3-dimensional Simulink.Parameter configuration variable reports error (#4519)
  • Invalid pointers created if BusAssignment blocks are connected to Merge blocks in some cases (#4515)
  • "bug: RsiType.eq is not implemented for type RealSet" for some models using arrays on inputs (#4508)
  • If multiple configuration variables violate constraints, Reactis only produces a warning for one (#4501)
  • Bad error message for out-of-range indices in Assignment block (#4497)
  • "Error: Data Type Mismatch" for some models with For or While subsystems (#4494)

Reactis for C V2019.0.1

The following bugs were fixed since V2019:

  • Disabled coverage metrics are displayed in the Tester launch dialog (#4020)
  • Syntax errors occur when using the API with MATLAB and gcc (#4360)
  • Value returned by API function rcRsmGetCoverageEnabled is incorrect (#4435)
  • Placement of warning icon for orphaned instrumentation code is sometimes incorrect (#4468)
  • Empty instrumentation code causes GUI to crash (#4466)
  • Spatial memory error incorrectly reported for complex structure access (#4470)
  • Instrumentation code is sometimes incorrectly marked as "orphaned" (#4491)
  • Importing of configuration variables from an .rsi file sometimes fails (#4537)

Reactis for C V2018.0.2

The following bugs were fixed since V2018.0.1:

  • Disabled coverage metrics are displayed in the Tester launch dialog (#4020)
  • Syntax errors occur when using the API with MATLAB and gcc (#4360)
  • Value returned by API function rcRsmGetCoverageEnabled is incorrect (#4435)
  • Spatial memory error incorrectly reported for complex structure access (#4470)
  • Importing of configuration variables from an .rsi file sometimes fails (#4537)

You may download the patches or full installers from the Reactis User Pages.

Best Regards,
The Reactis Team

Back to Patches Archive