e
We are pleased to announce the availability of Reactis
V2005.0.12 and Reactis V2005.1.9 (Beta)
V2005.0.12
The following bugs were fixed since V2005.0.11
- Accept mixed data types in Merge blocks.
- Accept integer values as inputs to Switch Case blocks.
- Accept expressions in S-Function name field.
- Fixed wrong output of Look Up Table block that occurred when
``Use value below'' option was selected.
- Correctly handle the case when the top-level system name of a
Validator objective library does not match the file name of that library
(this can happen when a library is renamed outside Simulink).
- If a model file is associated with a non-default .rsi file and that .rsi file
no longer exists, remove the association.
- Fixed problem that caused a ``Backend process died unexpectedly (exit code 0)''
error message to be displayed on some systems.
V2005.1.9
The following features were added since V2005.1.8.
- Support Simulink From Workspace, From File and Signal Builder
blocks.
- Support mixed bus signals in Merge, Unit Delay, Memory,
Zero-Order Hold, Switch and Multiport Switch blocks.
- Tester now obtains better boundary value coverage for vector inputs.
The following bugs were fixed since V2005.1.7.
- Fixed bug introduced in V2005.1.8 that broke progress indicator in Tester.
- Correctly handle the case when the top-level system name of a Validator
objective library does not match the file name of that library (this can happen
when a library is renamed outside Simulink).
- Fixed problem where Tester could terminate suggesting 100 percent coverage
although some MC/DC targets remained uncovered.
- Support more than two arguments to Stateflow ``min'' and ``max'' functions.
- Support remapping of signal names in ``Bus Selector'' blocks when name is unique
but not referring to current bus architecture.
- If a model file is associated with a non-default .rsi file and that .rsi file
no longer exists, then remove the association.
- Fixed wrong output of ``Look Up Table'' block that occurred when
``Use value below'' option was selected.
- Fixed problem that caused a ``Backend process died unexpectedly (exit code 0)''
error message to be displayed on some systems.
You may download the patches or full installers from:
https://reactive-systems.com/login.msp
Best Regards,
The Reactis Team