June 10, 2026
Dear Reactis User:
We are pleased to announce the availability of:
The V2026 release of Reactis includes all bug fixes that were included in patch releases through V2025.2.2 plus the new features listed below.
A number of improvements have been made to static model reachability analysis and solver capabilities during test case generation. The goal of these enhancements is to identify more targets as unreachable (and more assertions as impossible to violate) during static analysis and to enable Tester to cover more targets during test generation. The changes include the following:
The existing signal-tracing mechanism in Reactis has been extended to trace into and out of Stateflow diagrams. If a signal entering or exiting a Stateflow chart is highlighted, Reactis will highlight all occurrences of the corresponding Stateflow variable in the Stateflow chart. If a variable is clicked within a Stateflow chart, Reactis will highlight all other occurrences of that variable within the chart. If the highlighted variable is a chart input or output, the corresponding signal in Simulink will also be highlighted.
For Variant Subsystems with activation time Code compile, Startup, or Runtime, Reactis now lets you use configuration variables to select the active variant. This means that for Variant Subsystems, coverage of all variants can be achieved within a single test suite and without re-importing the model.
Furthermore, a new API function ``rsRsiCreateVariantConfigurationSets`` automatically imports the configurations within Simulink.VariantConfigurationData objects into Reactis. This enables Reactis Tester to cover all variant configurations defined within the objects. The import automatically creates configuration variables and configuration variable sets in Reactis that correspond to the Simulink variant configurations and their control variables.
Reactis now tracks coverage for Configuration Variable Sets. Each set is shown in the Configuration Variables panel in the model hierarchy and colored according to whether it has been covered or not. A Configuration Variable Set is considered covered when at least one simulation step has been taken where the value of each configuration variable matches its constraint from the Configuration Variable Set.
Apart from improving the visibility of whether a set has actually been used during simulation, the new tracking also enables Reactis Tester to automatically create tests that cover each defined Configuration Variable Set.
The following Simulink features are newly supported in Reactis V2026:
The V2026 release of Reactis for C includes all bug fixes that were included in patch release V2025.0.1, plus the new features listed below.
V2026 focuses on improved testing flexibility and AUTOSAR whole-component testing. Key additions include pragma-based coverage control and whole-component AUTOSAR testing. The V2026 release of Reactis for C includes all bug fixes that were included in patch release V2025.0.1, plus the following new features.
Reactis for C tracks how thoroughly tests exercise your code using a collection of coverage metrics, including statement coverage, decision coverage, condition coverage, MC/DC coverage and others. For each metric, a set of coverage targets are identified within your code. Reactis Simulator then tracks whether each target has been exercised and Reactis Tester attempts to generate tests that maximize the number of targets exercised.
While you typically want to test your entire program, sometimes you may wish to focus on one part of your code and not on others. To facilitate such focused testing, V2026 introduces a new C pragma to disable target generation for a section of code. ``#pragma REACTIS coverage off`` stops target creation for all lines which follow, until a line containing ``#pragma REACTIS coverage on`` is reached. There is no need to modify your source files, since these pragmas can be added as instrumentation code. This lets you precisely target the important sections of your code, while ignoring irrelevant parts. The new pragmas are especially useful for testing code that accesses legacy code, external libraries, or third-party code not under your control.
V2025 introduced an AUTOSAR import wizard that, given a set of ARXML files describing an AUTOSAR component, generates a minimal RTE, build file, and harness necessary to test a single runnable of the component in Reactis for C.
V2026 extends the import tool to facilitate testing a whole component, i.e. all runnables of the component together. When importing a component with multiple runnables, Reactis for C automatically generates a scheduler that triggers each runnable as specified in the AUTOSAR component.
Previously, only single runnables could be tested in isolation. V2026 now enables integrated testing of all runnables with automatic scheduler generation.
V2026 offers a new global option in the C Code tab of File > Global Settings... that lets you configure Reactis for C to store compiler-generated files in a separate folder. You can place all files in a subfolder of the folder containing the build (.rsm) file, or select a single folder to contain all compiler-generated files. This makes it easy to keep track of compiler-generated files, and delete them when they are no longer needed.
When importing a Reactis for C test harness from a ``.rsi`` file, names which originate from a Simulink data dictionary (``.sldd``) file are now automatically matched to variables in the C code with the same name. This eliminates the need to manually match data dictionary variables.
A new menu choice File > Open Build File Folder opens the folder containing the currently open build file in Windows Explorer. This is useful when you need to access files outside of Reactis.
The V2026 release of Reactis Model Inspector includes the following new features.
The existing signal-tracing mechanism in Reactis has been extended to trace into and out of Stateflow diagrams. If a signal entering or exiting a Stateflow chart is highlighted, Reactis will highlight all occurrences of the corresponding Stateflow variable in the Stateflow chart. If a variable is clicked within a Stateflow chart, Reactis will highlight all other occurrences of that variable within the chart. If the highlighted variable is a chart input or output, the corresponding signal in Simulink will also be highlighted.
The following Simulink features are newly supported in Reactis Model Inspector V2026:
You may download the patches or full installers from the Reactis User Pages.
Best Regards,
The Reactis Team