Reactis for Simulink V2021.2.3 Resolved Issues


Product Major Version Patch Status
Reactis for Simulink 2021.2 3 Resolved

IdSubmitted
50152022-06-06
Sample rates within atomic subsystem not honored
50322022-06-28
rsTesterGetSuite produces an error if test suite generation has not finished
50372022-06-27
"bug: invalid pointer" in some models containing Bus Assignment blocks
50522022-07-19
bug: signal type mismatch: datatype[1x1] datatype for some Stateflow charts with virtual bus inputs
50642022-08-10
"Error: expected numeric data type" when initialing DataStoreMemory of bus type with structure value
50692022-08-12
"Error: Data type or size mismatch" for some buses exiting referenced models
50772022-09-01
Trigonometric Function block performing asin or acos with input saturation produces simulation error for non-scalar input
50842022-09-12
Error "Conversion to logical from Simulink.Parameter is not possible" for some variant subsystems
50952022-09-26
Reactis reports "Invalid base type" when attempting to change a enumerated type constraint within the API
50962022-09-26
Issues with Simulink.Parameter objects containing enumerated types within buses
51012022-09-30
Interval coverage metric not available in API coverage report configuration
51042022-09-30
Excessively large warning messages may slow down Reactis startup
51132022-10-04
Relational Operator block inside Compare To Zero block shows incorrect operator
51152022-10-06
MATLAB API function rsTesterStart does not report errors with its arguments
51182022-11-08
Backend occasionally fails with error code 0xC0000005
51252022-11-23
Orphaned validator objective not removed from RSI file
51262022-11-22
Some API functions report error for output port names containing special characters